+86-13901877864
sales@yunyunhb.com
product Center
Table adjustment 212
Table adjustment 212
product descriptions

name said

oxidation Auxiliary Agent

model/specification

212

characteristics

The surface conditioner 212 can prevent uneven coloring, make the dyeing effect better, increase the dyeing ability, and the appearance is light white or yellow acidic powder.

conditions of use

 

 

 

 

standards

scope

Table adjustment 212

50 g/l

40-75 g/l

temperatures

55℃

45-60℃

of time

3 minutes

1-5 minutes

pH (℃)

2.0

1.3-2.5

the heating

Heating with Teflon heater or steam coil (SUS316)

cylinder material

Stainless steel (SUS304) or acid-proof plastic cylinder

stir

Air or mechanical agitation

filtered

not need

 

 

Process flow:

Degreasing (AL-CLEAN DA5, DAC-8)→ Sanding (AL-EN)→ Stain Removal (AL-D40)→ Chemical Grinding (AL-CP2, PP-541N)→ Stain Removal (AL-D40)→ Anodizing (Sulfuric Acid)→ Pretreatment for Coloring (Topdressing 212)→ Coloring (Peramet Dye)→ Blocking (PLS or PHS-5000)→ Drying

 

pH adjustment:

  • Sodium hydroxide solution can be used to increase the pH value of the tank solution.
  • To reduce the pH value of the tank liquid, use a meter to adjust 212 or nitric acid solution.

package and storage

10 kg/box, stored in a cool and dry warehouse, strictly prohibited from direct sunlight, high temperatures and high temperatures, must be covered and sealed after use.

return list